Quote Now

Flexo Plate Back Exposure Test: Setting Floor and Relief

Written by
Feng Yan
Last update:

By Feng Yan, Technical Engineer, CTPPressLast updated: November 2026Quick answer: Back exposure is UV exposure…

By Feng Yan, Technical Engineer, CTPPress

Last updated: November 2026

Quick answer: Back exposure is UV exposure through the plate base. It builds the floor, and the floor sets the relief depth: more back exposure gives a thicker floor and shallower relief. Set it first with a step test: expose a strip in timed steps, wash out, measure the floor of each step, plot and choose the time that gives the target relief. Then run the main exposure test at that back exposure, and repeat both after a lamp change.

Key takeaways

  • Back exposure hardens the plate from the base and builds the floor. More back exposure gives a thicker floor and shallower relief.
  • Main exposure through the film or mask forms the dots, lines and shoulders. Too little and small dots do not stand; too much and the dots grow.
  • Set back exposure first with a step test on a strip, then run the main exposure test at that back exposure.
  • Data sheet times are only a starting point. Your lamps, exposure unit and washout decide the result, so test again after a lamp change.
  • Check thickness and hardness on incoming plates, and fix washout pressure and speed for every test, or the results cannot be compared.

The floor came out too thick after we changed the lamps. Small dots do not hold and longer exposure fills in the shadows. Relief depth changes from one week to the next. These problems start when exposure times are copied from a data sheet and never tested on your own line. This guide covers both exposure tests and a record sheet, so the same floor comes out on every plate. For the full plate making sequence, see our flexo plate making process guide.

What back exposure and main exposure do

A photopolymer flexo plate is exposed to UV light from two sides.

  • Back exposure goes through the polyester base. It hardens a layer of polymer from the back, and this layer is the floor. Everything above the floor that main exposure does not reach is removed in washout, so the floor decides the relief depth. More back exposure gives a thicker floor and shallower relief; less back exposure gives a thinner floor and deeper relief.
  • Main exposure goes through the film negative or the laser-ablated mask. It hardens the image down to the floor and builds the dot shoulders, so it sets the dot area, the shoulder angle and how open the reverse lines stay.

The dots stand on the floor, so in common practice back exposure is set first, and the main exposure test then shows what the image needs on that floor. If you change back exposure later, check main exposure again. Our relief depth guide explains how base, floor and relief make up the plate.

Check incoming plates before you test

A test on a plate with the wrong thickness or hardness gives the wrong answer, so check the plates first.

  • Appearance. No lifted film, no streaks, a flat sheet with no creases, and an even colour.
  • Thickness. Measure several points on the plate with a thickness gauge and take the mean. The plus error is the highest reading minus the mean; the minus error is the mean minus the lowest reading. Suppliers typically hold about ±0.010 to 0.015 mm within one plate and about ±0.025 mm from plate to plate. One published study found that ±0.040 mm between plates did not affect print quality, but suppliers still work to ±0.025 mm. The data sheet decides for each grade.
  • Hardness. Measure Shore A on an exposed plate, not on a raw one, and compare it with the value the supplier states. For 3.94 mm plates, suppliers usually allow about ±2 Shore A around that value.
  • One plate type per job. Use the same plate type for every colour of a job.

Our plate test protocol shows how to record these checks, and the flexo plate thickness guide explains how gauge is chosen.

The back exposure step test

A common belief is that the back exposure time on the data sheet is right for your plate room. It is not. Data sheet times are only a starting point; your lamps, exposure unit and washout decide the floor, so run your own step test. The test links the energy of your light source to the relief depth on your plate.

  1. Cut a strip. From the edge of a plate, cut a strip 15 to 20 cm long and 2 cm wide.
  2. Make a reference solid. Cover the strip except for a 1 cm band and expose that band from the front until it is fully cured. This solid has the full plate height and is your measuring reference.
  3. Expose the steps. Use a cover strip to give each section of the strip a different back exposure time. Start from the supplier’s recommended time and place steps on both sides of it.
  4. Wash out and dry. Use your normal washout and drying settings, with washout pressure and speed fixed and written down.
  5. Measure. Measure the reference solid and each step with the thickness gauge. Each step shows the floor that its back exposure built. Relief depth is the total plate thickness minus the floor.
  6. Plot and choose. Plot back exposure time against floor thickness or relief depth. Choose the time that gives the target relief for the grade. If no step hits the target, run a second test between the two nearest steps instead of guessing.

The target relief comes from the plate supplier. For the plates we supply, each grade’s relief depth and starting back exposure time are on the digital flexo plates and analog flexo plates pages.

The main exposure test

Run the main exposure test at the back exposure you have just chosen. Use a test negative, or a test file imaged on the mask, that holds solids, positive and reverse lines, tints and isolated dots. For 1.14 mm plates, one common test form uses tints at 100, 120 and 150 lpi from 2% to 90%; for 3.94 mm plates, tints at 60, 85 and 100 lpi from 5% to 90%. Expose the form at increasing times, with washout pressure and speed fixed and recorded.

Many operators believe that if small dots do not hold, they should give more main exposure. But longer main exposure holds small dots and makes the other dots grow. Find the balance and set the floor first. Judge each exposure in this order:

  1. No fine cracks on the plate surface. This sets the lowest exposure you can use.
  2. Small dots stand after washout, including isolated dots.
  3. Dot gain is within your standard. More exposure means more dot gain.
  4. Dot shoulder. A sharp dot has a small contact area and gains little, but its base is not stable and under pressure it gains more. A middle shoulder angle is the aim: about 30° on 3.94 mm plates and about 26 to 33° on 1.14 mm plates, where a dot profile can be measured.
  5. Reverse lines stay open. The reverse lines show the exposure latitude. A dot analyser that shows the change in dot size is a simpler way to judge the result.

Choose the shortest exposure that meets every point. If none does, decide by the job: highlight detail or tone.

Lamp age, new lamps and a new exposure unit

Exposure is intensity multiplied by time. If the lamps give less UV, the same time gives less exposure, and the floor and the dots change with it. “The lamps still light, so they are fine” is not a test. UV lamps lose output as they age, even while they still light.

  • Test again after a new lamp set, a new exposure unit, a new plate type or new washout settings.
  • Between lamp changes, repeat the step test at regular intervals. If the floor at the same time has changed, so have the lamps or the washout.
  • Write the lamp hours on every test record, so a drift in relief depth can be traced.

The reference times on our plate pages were measured with 80 W UV light giving 10.4 mW/cm² at 365 nm, at 24 to 30 °C. Your unit is different, so the test on your own line decides. Exposure and washout units are on our flexo plate processors page.

Faults from wrong back or main exposure

Symptom Likely cause Check or fix
Floor too thick, relief shallow, reverses fill in Back exposure too long, or new lamps with the old time Repeat the step test; shorten back exposure
Floor too thin, relief deep, fine dots and lines bend or wash away Back exposure too short Repeat the step test; lengthen back exposure; then check main exposure
Relief depth changes from week to week Lamp ageing, washout drift, no routine test Log lamp hours; repeat the step test on a schedule
Fine cracks on the plate surface Main exposure too short Increase main exposure above the crack limit
Small dots do not stand Main exposure too short Increase main exposure and check dot gain in the other tones
Dots grow in midtones and shadows Main exposure too long, often to save small dots Reduce main exposure; decide between highlight detail and tone
Sharp dots gain heavily under impression Shoulder angle too steep, dot base not stable Adjust main exposure towards the target shoulder angle
Test results do not repeat Washout pressure or speed changed between tests Fix and record washout settings, then test again
Colours in one job print differently Different plate types mixed in one job Use one plate type for every colour

A record sheet for exposure tests

Keep one sheet per test with these fields.

Field What to write
Plate Grade, nominal thickness, batch, measured thickness (mean, plus and minus error), Shore A on an exposed plate
Equipment Exposure unit, lamp hours or date of last lamp change, room temperature
Washout and drying Washout pressure, speed and time; drying time and temperature
Back exposure steps Time of each step; measured floor; relief depth; chosen time
Main exposure steps Time of each step; fine cracks yes or no; smallest dot held; dot gain; shoulder angle if measured; reverse lines open or filled
Result Chosen back and main exposure, who ran the test, date, next test due

With the sheets on file, a drift can be compared with the last good test. We supply photopolymer flexo plates with a data sheet for each grade that gives starting exposure times and the target relief.

FAQ

What is back exposure in flexo plate making?

Back exposure is UV exposure through the polyester base. It hardens the floor of the plate, and the floor decides the relief depth. More back exposure gives a thicker floor and shallower relief.

How do you do a back exposure step test?

Cut a strip 15 to 20 cm long and 2 cm wide, expose a 1 cm band from the front as a reference solid, give each section a different back exposure time, wash out and dry, then measure each step. Plot time against floor or relief and choose the time that gives the target relief.

Why is back exposure set before main exposure?

The dots stand on the floor, so the floor is fixed first. If you change back exposure later, check main exposure again.

How do you set main exposure on a flexo plate?

Expose a test form at increasing times with fixed washout settings. Choose the shortest time with no fine surface cracks, small dots that stand, dot gain within your standard, a suitable shoulder angle and open reverse lines.

Does lamp age change flexo plate exposure?

Yes. Exposure is intensity multiplied by time, and UV lamps lose output as they age. Repeat the step test after a lamp change and at regular intervals.

What thickness tolerance should flexo plates have?

Suppliers typically hold about ±0.010 to 0.015 mm within one plate and about ±0.025 mm from plate to plate. The supplier’s data sheet decides for each grade.

Setting up a new plate type or a new exposure unit. Request trial plates with your plate thickness, exposure unit and washout type, or ask a technical question.

Disclaimer: the test steps and values on this page are general plate room practice and for reference only. Exposure times for your plates depend on your exposure unit, lamps and washout; confirm the target relief and starting times in the data sheet for each grade.

About Feng Yan

Feng Yan is a technical engineer at CTPPress with more than 20 years in the printing industry and extensive front-line experience supporting printing plants. Feng specialises in solving the difficult problems printers run into in production.

Talk With Author >>

Start Your Business With Us

Simple Contact Form

Tell us what you need

Request a Quote

Tell us which printing plates or equipment you need, including specifications, quantity and destination. Use the form to send your enquiry.

Aluminium coils and printing plate production equipment
Product Enquiry

Request an Instant Quote

We reply within 24 hours on working days

Product Enquiry
Aluminium coil on an offset plate production line

Send an Enquiry


Product Enquiry
Chat on WhatsApp