Quote Now

Fountain Solution Guide: pH, Conductivity and Mixing

Written by
Peter Zhang
Last update:

Fountain solution for offset printers: what it is made of, pH, conductivity and temperature checks,…

By , Sales Manager, CTPPress

Last updated: November 2026

Quick answer: Fountain solution is the water-based dampening liquid that keeps the non-image areas of an offset plate ink-free. It is mostly water plus a concentrate (acid buffer, gum, wetting agents, biocide) and sometimes alcohol. Keep it stable by using consistent water, dosing the concentrate by measurement, and checking pH, conductivity and temperature every shift.

Key takeaways

  • Fountain solution protects the non-image area of the plate; it is not just “water in the dampening tray”.
  • pH tells you whether the buffer is working; conductivity tells you how much concentrate (and contamination) is in the tank. Measure both.
  • Known, consistent water quality matters as much as the concentrate.
  • Alcohol-free running works, but the dampening rollers, settings and concentrate must suit it.
  • Plate type matters: processless and CTcP plates have their own start-up and chemistry notes in the grade TDS.

Most pressroom problems blamed on the plate or the ink start in the dampening system. A fountain solution that drifts during the shift slowly changes how the plate takes water, and the operator compensates with more water or more ink until the job starts toning or the colour moves. This guide is about the chemistry and the routine checks. How much water to run is covered separately in our guide to finding the ink and water balance. The hardware side, from roller types to settings, is covered in our guide to the offset dampening system.

We manufacture offset plates, not fountain solution, and we do not supply it. The advice below is general pressroom practice; always follow the concentrate supplier’s instructions and the plate grade TDS.

What does fountain solution do in offset printing?

Offset lithography works because the non-image area of the plate (grained, anodised aluminium covered by a thin hydrophilic layer) prefers water, while the image area prefers ink. The fountain solution does four jobs:

  • Wets the non-image area with a thin, even film so ink cannot settle there.
  • Keeps the non-image area desensitised: the gum in the concentrate refreshes the hydrophilic layer during the run.
  • Controls emulsification: a small amount of water must mix into the ink, but not too much.
  • Cools and cleans the plate surface and carries away paper dust and loose particles.

When any of these jobs fails, the visible symptoms are tinting, scumming, slow drying, piling on the blanket or a weak, washed-out print. For slow drying that marks the back of the next sheet, see ink set-off. For dry ink that rubs off as a powder, see ink chalking.

What is fountain solution made of?

A typical working solution is mostly water with a small dose of concentrate. A common starting point in the industry is a concentrate dose of roughly 2 to 4 percent, but the correct dose is the one written on the concentrate’s data sheet.

Component Purpose What goes wrong if it is off
Water Carrier, forms the dampening film Hard or variable water changes buffering, can cause deposits on rollers
Acid buffer Holds pH in the working window Too acidic: slow ink drying, attack on the plate; too weak: tinting
Gum (gum arabic or synthetic gum) Keeps the non-image area hydrophilic Too little: scumming risk; too much: blinding risk in image areas
Wetting agents / alcohol or alcohol substitute Lowers surface tension so a thin film spreads evenly Too little: uneven dampening; too much: over-emulsified ink
Biocide Stops algae, bacteria and fungus in the tank and pipes Slime in the circulator, blocked filters, odour
Corrosion inhibitors, anti-piling agents Protect press metal, reduce build-up Roller stripping, blanket piling

pH, conductivity and temperature: what to measure

Three numbers describe a healthy fountain solution. Write them on a simple log sheet at the start of every shift.

  1. pH. Many concentrates are designed to run in a slightly acidic window, typically around pH 4.8 to 5.5. pH alone is not a dose control: a well-buffered concentrate holds almost the same pH over a wide range of doses.
  2. Conductivity. This is the number that tracks the concentrate dose. Measure the incoming water first, then the mixed solution, and compare with the concentrate supplier’s dose chart. A conductivity that keeps rising during the week, without more concentrate added, usually means contamination from paper coating, ink or powder.
  3. Temperature. Most recirculation units are cooled. A common target in the industry is roughly 10 to 15 °C at the tank. Warmer solution evaporates alcohol faster and lets the ink emulsify more.

Calibrate the pH and conductivity meters regularly. A meter that is not calibrated is worse than no meter, because operators trust it.

Alcohol vs alcohol-free fountain solution

Isopropyl alcohol (IPA) lowers surface tension and helps a thin dampening film spread quickly. Older dampening systems were set up around it, often in the range of about 8 to 12 percent. Many printers now run reduced-alcohol or alcohol-free, using an alcohol substitute in the concentrate, for health, cost and emission reasons.

A common belief is that “more alcohol always fixes it”. In practice, adding alcohol to cover a problem hides the real cause (worn or glazed dampening rollers, wrong roller settings, hard water, a contaminated tank) and adds over-emulsified ink on top. A measured concentrate dose, controlled conductivity and temperature give more stable dampening than extra alcohol does.

If you move to alcohol-free running: check dampening roller hardness and settings first, use a concentrate made for alcohol-free running, and expect a short learning period for the operators.

Mixing and changing fountain solution

Many plants mix by eye: “a cup of concentrate in the tank”. That is how every operator ends up mixing the fount differently. A repeatable routine:

  1. Know your water. Tap water varies by season and by source. Water hardness and quality change how the concentrate buffers, so test the water, and if it varies a lot, consider treated water (for example reverse osmosis with controlled re-hardening as advised by the concentrate supplier).
  2. Dose by measurement: use a dosing unit or a measured container, never “a splash”.
  3. Mix, circulate and then measure pH and conductivity before the first make-ready.
  4. Top up with pre-mixed solution, not plain water or neat concentrate.
  5. Drain, clean and refill the tank, filters and pipes on a fixed schedule. Many plants do this every 1 to 2 weeks, more often on long runs with coated paper or high powder use.

Fountain solution problems table

Symptom Likely fountain-solution cause Check / fix
Uniform tint over the non-image area Ink over-emulsified; dose too low or too much alcohol Check conductivity and alcohol; see scumming vs toning
Ink drying slowly on the sheet pH too low, too much concentrate, too much water Check dose and pH; reduce water to the minimum
Image areas refuse ink Gum build-up, very strong solution Check dose; see plate blinding causes
Conductivity rising through the week Contamination from paper, ink, powder Drain and clean the circulator; check filters
Slime, odour, blocked filters Biological growth Clean system with a system cleaner; check biocide
Dampening uneven across the plate Low wetting, warm solution, glazed rollers Check temperature and rollers before adding alcohol

If the plate itself is suspected (for example an under-developed plate that scums from the first sheet), go to our CTP plate troubleshooting guide.

Unstable fountain solution shows up as drifting tone values, which makes it harder to hold the offset aims in ISO 12647-2. The same ink set, often specified to ISO 2846-1, prints differently when pH or conductivity moves.

Fountain solution and plate type

Modern CTP plates run with standard pressroom fountain solutions, but a few plate-specific points are worth knowing:

  • Processless plates clear their non-image coating on press with ink and fountain solution. The start-up sequence and dampening settings matter; see our processless plate start-up guide and the processless CTP plates page.
  • Thermal and CTcP plates are developed in the plate room, so the non-image area is clean when it reaches the press. Strongly acidic or over-dosed fountain solution can still shorten plate life on long runs. See what causes plate wear.
  • UV inks usually come with their own dampening recommendations. Plate choice also changes; see UV and LED-UV offset printing.

FAQ

What is fountain solution made of?

Fountain solution is mostly water with a small dose of concentrate. The concentrate contains an acid buffer, gum (gum arabic or synthetic), wetting agents or an alcohol substitute, biocide and corrosion inhibitors. Some presses also add isopropyl alcohol.

What pH should fountain solution be?

Many concentrates are designed for a slightly acidic window, typically around pH 4.8 to 5.5. Follow the concentrate data sheet, and use conductivity rather than pH to control the dose.

How do you measure fountain solution conductivity?

Use a calibrated conductivity meter. Measure the incoming water first, then the mixed solution, at the temperature the meter is compensated for. Compare the difference with the concentrate supplier’s dose chart and log it every shift.

Can you print without alcohol in fountain solution?

Yes. Many printers run alcohol-free with a concentrate made for it. Dampening roller condition and settings must be correct first, because alcohol can no longer hide roller problems.

How often should fountain solution be changed?

It depends on volume, paper and powder use. Many plants drain, clean and refill the tank and filters every 1 to 2 weeks, and sooner if conductivity keeps rising or the system smells or forms slime.

Checking whether a dampening problem is really a plate problem? Request a quote — send your press size, plate gauge, ink type and current plate grade. Or request trial plates / contact us.

Disclaimer: values on this page are typical and for reference only; final specifications, MOQ, price and lead time are subject to the grade TDS and the quotation.

About Peter Zhang

Peter Zhang, Sales Manager at CTPPress

Peter Zhang is Sales Manager at CTPPress, helping printers and dealers choose CTP plates, flexo plates and prepress equipment. Questions about a plate or machine? Contact us and we will reply with a specific recommendation.

Talk With Author >>

Start Your Business With Us

Simple Contact Form

Tell us what you need

Request a Quote

Tell us which printing plates or equipment you need, including specifications, quantity and destination. Use the form to send your enquiry.

Aluminium coils and printing plate production equipment
Product Enquiry

Request an Instant Quote

We reply within 24 hours on working days

Product Enquiry
Aluminium coil on an offset plate production line

Send an Enquiry


Product Enquiry
Chat on WhatsApp